Na-Ahịrị nkenke Air conditioner (Link-Thunder Series)

Nkọwa nkenke:


Product Ihe

Ajụjụ

Link-undergbè Eluigwe usoro na-ahiri nkenke ikuku conditioner, na uru nke ike ịzọpụta, mma na a pụrụ ịdabere na ọgụgụ isi akara, kọmpat Ọdịdị, elu usoro, àjà ihe ọ highụ highụ SHR na obi jụrụ nso okpomọkụ isi iyi, n'ụzọ zuru ezu igbo ihe jụrụ chọrọ nke data center na elu njupụta ọkụ.

Njirimara
1. High arụmọrụ na Energy Azọpụta
-O kacha mma imewe nke okpomọkụ Exchanger na ikuku duct site CFD, na elu arụmọrụ na ala-eguzogide maka okpomọkụ na uka nyefe
-Ultra dị elu nke nwere ezi uche na-ezere ọnwụ nke humidification na dehumidification ugboro ugboro
-Use elu- oru oma na eco refrigerant R410A dị ka ọkọlọtọ
-High- nkenke electronic mmeba valvụ
-High- oru oma inverter Compressor, ọgụgụ isi jụrụ ikike ukpụhọde
-Stepless ọsọ ofufe
-High- nkenke PID Damper (chilled mmiri ụdị)
-Stepless Speed ​​Scythe Type Jụrụ Fan
-Optimal akara iwu ana achi achi kacha ike- azọpụta arụmọrụ nke nkeji

2. High pụrụ ịdabere
-365 ụbọchị 7 × 24- oge nkwụsị ọrụ arụmọrụ
-Anwale akụkụ niile ma nyochachaa ya
-Safe na a pụrụ ịdabere na PTC eletriki kpo oku
-Condensing mgbapụta na mmiri larịị akara dị ka nke ọma dị ka nke ọma dị ka a pụrụ ịdabere oyiri nchedo nke mgbochi ujọ na mgbochi mmanụ- ikwafu aghụghọ
-Ezigbo njikere nchedo na akpaaka nchoputa
- N'ikwekọ na iwu nchekwa, asambodo EMC na CE

3. Ọgụgụ Isi
-Human-igwe Nkọwapụta ihu igwe
- Nnukwu ihuenyo LCD buru ibu
-Humanized imewe na onye- aka ọrụ
-Nhọrọ Interface (English / Chinese)
-Operation mode ngosi (gụnyere friji, kpo oku, dehumidification, humidification)
- A na-egosipụta ihe oyiyi agba agba dị iche iche
- Trendchart gosipụtara data okpomọkụ na iru mmiri
-Echekwa na gosipụta kacha 400 njikere ndekọ
-Nchedoro ndi agha
-Complete akpaaka nchedo na njikere ọrụ
-Auto nchoputa
-Full oke mmesho na ukpụhọde
-Auto Malitegharịa ekwentị
-Nchọpụta mmiri-leakage
- Ọkụ na anwụrụ ọkụ mkpu
-Echekwa ọkụ
-Emekọrịta Control
-Standard RS485 nkwurịta okwu interface na model- bus nkwurịta okwu protocol
-Teamwork akara nke kacha 32 nkeji
-Data ndabere, adiana na cascade zere agbụrụ na-agba ọsọ
-Disaster mgbake nlekota
-LONWORK, BACNET ma ọ bụ Ethernet nhọrọ protocol

4. Advanced Usoro
-ISO njikwa mma na mmepụta dabere (TPS)
- Mmepụta usoro maka akụrụngwa IT
-Fine na ezigbo nwa kabinet ọkụ data center n'ụzọ zuru okè
-High- ike etiti adabara oké osimiri, ala na ikuku njem

5. Ndozi Mfe
-Nsogbu oriri / iyuzucha n'ọdụ ụgbọ mmiri adopts ROTAL- LOCK ejiri njikọta maka mfe mmezi
-Fan na moto direct- jikọrọ integral imewe, ọ dịghị mkpa ịgbanwe belt
-Na ihu uzo uzo uzo na azu uzo di

6. vingchekwa Ime ụlọ
-Cabinet nwere ọkọlọtọ akụkụ na kọmpat na modular imewe
-Save echichi ebe na mmezi ohere ka kwere omume

7. Na-eme mgbanwe maka gburugburu ngwa dị iche iche
-Nwere ike ịrụ ọrụ ọnọdụ okpomọkụ dị gburugburu - 40 ~ + 55 ℃
-Long-ejikọta anwụrụ na elu-dobe imewe
-Eco aghụghọ na nnabata ROHS, REACH na wdg.
-CE, UL na TUV asambodo nwetara
-Ndenye nzaghachi ahịa na mgbanwe ahaziri ahazi ngwọta

Ngwa
Centerlọ Ọrụ Data Dijitalụ
Ebe nchekwa data nke akpa
Ebe nchekwa data dị elu-okpomọkụ


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ma zitere anyị ya