High Quality Downflow Air Handler Factory - Suspended DX Air Handling Unit – Airwoods
High Quality Downflow Air Handler Factory - Suspended DX Air Handling Unit – Airwoods Detail:
Commercial Building Fresh Air & Temperature Solution
Advanced Low Noise Technology
3-Side U Type Heat Exchanger Structure
3-side U-type heat exchanger makes effective use of fan airflow, fully expands the heat transfer area and greatly improves the heat transfer efficiency without increasing the unit space. Compact structure, high strength, more convenient on installation and maintenance. Aluminum fin with hydrophilic film is adopted to improve heat transfer coefficient of wet film and overall heat transfer coefficient of unit. |
Long Tube Design
The length of tube pipe connection between indoor unit and outdoor unit can be 50m, and the highest drop is 25m. It is more convenient to install the indoor and outdoor unit at project site. |
High Efficiency Heat Transfer Fin
Copper tube with Ø7.94 high tooth and high internal thread, moderate flow rate, heat exchange and defrosting comprehensive performance is the best.
Ø7 copper tube spacing is too small, frost effect on heat transfer, frost thickness, affect the defrost time.
Control System
Wire controller is simple and convinient, which mostly applies at small and medium-sized business area.
*Heat pump type: cooling/heating/fresh air supply
*Temperature setting range: 16~32°C
*Timing switch on/off
*LCD displayer, displaying setting temperature, operating mode, real time clock(optional),
week(optional), on/off, and fault.
*Automatically restart after reconnecting power
Functional Control System
Building system based on MODBUS can connect to central control system by MODBUS communication interface, realizing central control without connecting to conversion equipment, which is suitable for medium to large-sized air conditioning system.
Dual Temperature Sensors
Innovative design with two temperature sensors, one at return vent, and one at the control panel,
to detect the indoor temperature around the room, and make sure the hot wind(winter heating
mode) would be sent to each corner of the room uniformly.
Cold Wind Prevention, to Provide The Best Comfort of Heating
For heating in winter, when the AHU start, the coil-fin will be pre-heated before supply fan starts; when the AHU is under defrosting mode, AHU supply fan will stop; when defrosting is over, the
coil-fin will be also pre-heated before supply fan start again.
Specification of Suspended DX Air Handling Unit
Product detail pictures:
Related Product Guide:
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for High Quality Downflow Air Handler Factory - Suspended DX Air Handling Unit – Airwoods , The product will supply to all over the world, such as: Comoros, Austria, Brunei, Our solutions are produced with the best raw materials. Every moment, we constantly improve the production programme. In order to ensure better quality and service, we now have been focusing on the production process. We have got high praise by partner. We are looking forward to establishing business relationship with you.
By Federico Michael Di Marco from Portland - 2018.11.02 11:11
This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
By Hannah from Seattle - 2017.06.29 18:55