Factory Promotional Heat Pump Air Handler Factory - Suspended DX Air Handling Unit – Airwoods
Factory Promotional Heat Pump Air Handler Factory - Suspended DX Air Handling Unit – Airwoods Detail:
Commercial Building Fresh Air & Temperature Solution
Advanced Low Noise Technology
3-Side U Type Heat Exchanger Structure
3-side U-type heat exchanger makes effective use of fan airflow, fully expands the heat transfer area and greatly improves the heat transfer efficiency without increasing the unit space. Compact structure, high strength, more convenient on installation and maintenance. Aluminum fin with hydrophilic film is adopted to improve heat transfer coefficient of wet film and overall heat transfer coefficient of unit. |
Long Tube Design
The length of tube pipe connection between indoor unit and outdoor unit can be 50m, and the highest drop is 25m. It is more convenient to install the indoor and outdoor unit at project site. |
High Efficiency Heat Transfer Fin
Copper tube with Ø7.94 high tooth and high internal thread, moderate flow rate, heat exchange and defrosting comprehensive performance is the best.
Ø7 copper tube spacing is too small, frost effect on heat transfer, frost thickness, affect the defrost time.
Control System
Wire controller is simple and convinient, which mostly applies at small and medium-sized business area.
*Heat pump type: cooling/heating/fresh air supply
*Temperature setting range: 16~32°C
*Timing switch on/off
*LCD displayer, displaying setting temperature, operating mode, real time clock(optional),
week(optional), on/off, and fault.
*Automatically restart after reconnecting power
Functional Control System
Building system based on MODBUS can connect to central control system by MODBUS communication interface, realizing central control without connecting to conversion equipment, which is suitable for medium to large-sized air conditioning system.
Dual Temperature Sensors
Innovative design with two temperature sensors, one at return vent, and one at the control panel,
to detect the indoor temperature around the room, and make sure the hot wind(winter heating
mode) would be sent to each corner of the room uniformly.
Cold Wind Prevention, to Provide The Best Comfort of Heating
For heating in winter, when the AHU start, the coil-fin will be pre-heated before supply fan starts; when the AHU is under defrosting mode, AHU supply fan will stop; when defrosting is over, the
coil-fin will be also pre-heated before supply fan start again.
Specification of Suspended DX Air Handling Unit
Product detail pictures:
Related Product Guide:
Using a full scientific good quality administration system, very good quality and superior faith, we win good standing and occupied this discipline for Factory Promotional Heat Pump Air Handler Factory - Suspended DX Air Handling Unit – Airwoods , The product will supply to all over the world, such as: Munich, Jeddah, Malaysia, We provide good quality but unbeatable low price and the best service. Welcome to post your samples and color ring to us .We will produce the goods according to your request. If you are interested in any products we offer, please feel free to contact us directly by mail, fax, telephone or internet. We are here to answer your questions from Monday to Saturday and looking forward to cooperating with you.
By Jacqueline from Tajikistan - 2018.05.22 12:13
The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
By Anne from Ireland - 2018.05.13 17:00